Products Home Page > Smart meter > Photoelectric Direct Reading remote meter > Direct-reading table wet liquid seal
Direct-reading table wet liquid seal
  • Direct-reading table wet liquid seal
  • Product name:

    Direct-reading table wet liquid seal

    Category: Photoelectric Direct Reading remote meter
    Product model: LXSY-15~25
Product details

Name: LXSYY-15E ~ 50E rotor liquid seal photoelectric direct reading remote meter

Uses: This series of water meter for drinking water usage. Residents (sub-table) or industrial use.


Conditions of Use:

Temperature class: T30

Pressure Level: MAP 10 / MAP 16

Pressure loss rating: △ P 63


Indication error limit:

From minimum flow (Q1) to excluding transitional flow (Q2) of the lower zone ± 5%

From the high zone of the transitional flow (Q2) to overload flow (Q4) of ± 2%


Characteristics and main technical parameters:

Multi-streaming technology;

Horizontal mounting, measuring range R = 80

Digital counter wheel with special liquid package, long-term clear reading

Movement, using high-quality materials, long life, stable and reliable performance, external adjustment (seal); ductile iron or copper shell case (Case spray)

Direct-reading module uses photoelectric direct reading technology to read data word round, compared with the conventional pulse table, it can be reduced to zero reading error, AMR metering system is ideal zero error product. Module uses low-power design, usually no power supply, it needs power only when the meter reading. The module can be installed directly in the base table counter, and assembled into the base table photoelectric direct remote meter reading, with the smart metering system equipment, complete smart meter reading copy cell data and sharing data with the billing center networking.


一、Features

1, reading the word round of data, compared with the conventional pulse table, it can be reduced to zero reading error;

2, low-power design, and only if the readings valve switch supplied with power;

3, the use of advanced data encoding and verification technology, high reliability communications;

4, in line with "electronic remote meter" (CJ / T 224-2012) standard;

5, compatible with a variety of communication protocols; DL / T645, CJ / T188 and internal protocols;

6, to meet the EMC, ESD, EMI and other electronic products, electromagnetic compatibility design requirements, to achieve industry-leading level;

7, combined with the host computer system, to establish a remote automatic meter reading management system, the real meter reading, monitoring automation.


二、Second, the technical parameters

2, working voltage: DC 36V;

3, the working current:

Current meter reading ≤9.0mA

Quiescent current ≤1.3 mA

4, the working environment: temperature: -10 ℃ ~ + 45 ℃ Humidity: 0 ~ 95% RH;

5, Storage temperature: -25 ℃ ~ + 65 ℃;

6, with the host computer communication: M-bus field bus;

7, communication transmission speed: 2400 baud;

8, communication protocol: DL / T645, CJ / T 188 and an internal protocol (or user-specified statute);

9, the maximum transmission distance communication: 300m; (communication line specification AVVR2 × 0.75)

10, the bus pin ESD protection exceeding 10kV;

11, the short-circuit current protection;

12, for the bus open, short, idle fault protection.


The main technical parameters:

caliber DNmmMeasuring range Q3/Q1Traffic overload Q4Common flow Q3Transitional Flow Q2Minimum flow Q1Starting flowMinimum readingThe maximum reading
m3/hL/hm3
15803.1252.55031.25120.0000599999
1004025
1602515.6255
2002012.5
208054805016
1006440
16040256
2003220
25807.87512678.7517
100100.863
1606339.3758
20050.431.5
328012.51020012523
100160100
16010062.510
2008050
4080201632020050
100256160
16016010035
20012880
508031.2525500312.560
100400250
160250156.2540
200200125


● flow error curve


Pressure loss curve


● Dimensions and weight

Nominal diameterlong Lwidth Bhigh HConnection thread(D)weight(kg)
(mm)mm
15165/19099104G3/4B1.5/1.6
20190/19599106G1B1.7
25260/225104120G1 1/4B2.6/2.4
32260/230104120G1 1/2B2.8/2.7
40300/245125155G2B5.4/4.5
50300125155B2 1/2B7.2
280158175Flanged Press GB4216.4.84 D=165 D1=12514



● Conditions of Use

Working temperature no higher than 40 °c

Working pressure is less than 1MPa


Ningbo Shengde WaterMeter Co.,Ltd.Reserved.code

Adderss:Xin'an lndustry Zone, Xijiao, Ningbo, China Tel:+86-0574-88440229 Sales dep tel:

Contact person: Purchasing dep tel: E-mail:[email protected] Zip:315101

Copyright ? Sunway Hanguang Electric Manufacturing Limited

主站蜘蛛池模板: 涩涩亚洲| 中文字幕人妻一区二区在线视频 | 亚洲日本成本人观看 | 日本欧美大码一区二区 | 久久九九久久这里只有精品 | 日韩视频免播放在线观看 | 精品三级片免费网址AV | 91视频网店 | 99精品国产99久 | 日韩不卡高清 | 日本欧美成 | 亚洲欧美国产综合久久 | 国产我和| 美女人妖极品入口免费观看视频 | 国产偷国产偷亚 | 日韩激情五码视频中文字幕 | 国产熟女偷窥高 | 国内精品伊人久久久影院 | 性无码精品久久 | 18禁高潮娇喘出水长时间视频 | 91精品国产综合久久精品 | 中文国产日韩欧 | 欧美日韩不卡视频 | 国产免费成人电影 | 天天干夜操 | 亚洲无码一区二区三区在线观看 | 日韩精品不卡一区二区 | 亚欧影院 | 拍拍拍2025年韩国久久久久 | 韩国三级无码无遮床戏视频 | 国产精品人妻久久ai换脸 | 午夜看片国产 | 欧美激情国产精品视频 | 99精品久久久久精品双飞 | 91天堂 | 亚洲av无码专区在线播放 | 欧美丰腴丰满大屁股熟妇 | 天堂v在线观看视频 | 亚洲av无码天堂一区二区三区 | 专区欧美专区日韩专区 | 亚洲精品在线免费看 |